Frozen Beverage: Troubleshooting Frost Check

FB: Troubleshooting Frost Check


Troubleshooting ::  Frozen Beverage   ::  Frost Check

Introduction

As a diagnostic check, Spaceman may recommend performing a Frost Check to determine the functionality of the refrigeration system.  This test should ONLY be performed for diagnostic purposes and is NOT recommended to be performed on a regular basis.

Warning:  Operating the machine with the doors off is dangerous.  Please be careful not to place your hands or any objects inside the freezing cylinder when in operation.  Failure to do so may cause severe injury.

Troubleshooting Steps

  1. Drain, Rinse, and Disassemble your machine in accordance with your machine’s operator manual.
  2. Clean the interior of the cylinder, and ensure the dispensing door and beater parts have all been removed and set aside.
Warning:  Operating the machine with the doors off is dangerous.  Please be careful not to place your hands or any objects inside the freezing cylinder when in operation.  Failure to do so may cause severe injury.
  1. Turn the machine to FREEZE mode.

Note:  If your machine has multiple flavors, perform this test one side at a time.

  1. The motor should turn on, and a few seconds later the compressor and condensing fan should turn on.
  2. After approximately 30 seconds, your cylinder wall should begin to get very cold and start forming a thin layer of frost.  This indicates that your refrigeration system is working correctly.

Important: Allow machine to run for at least 1 minute before proceeding to not short-cycle the compressor

  1. Turn power to OFF.  
  2. If your machine has two flavors, repeat steps 3-6 for the second flavor.
  3. If both sides of your machine have frosted up in adequate time, then your refrigeration system is functioning correctly. Allow at least 5 minutes for the frost to thaw before reassembling your machine.



    • Related Articles

    • SS: Troubleshooting Frost Check

      Troubleshooting :: Soft Serve :: Frost Check Introduction As a diagnostic check, Spaceman may recommend performing a Frost Check to determine the functionality of the refrigeration system.  This test should ONLY be performed for diagnostic purposes ...
    • SS: 6210 Functionality Check

      Troubleshooting :: Soft Serve :: 6210 Functionality Check Introduction Often times, when troubleshooting issues with the machines, performing a detailed functionality check is a good way to rule out, or pin point, what issues may be occurring with ...
    • FB: Verify Machine Performance

      Troubleshooting :: Frozen Beverage :: Machine Performance Introduction During periods of peak production, high ambient temperatures, or busy seasons, it may sometimes seem like your frozen beverage machine is not keeping up.  Often, this is a result ...
    • SS: Functionality Check

      Troubleshooting :: Soft Serve :: Functionality Check Introduction Often times, when troubleshooting issues with the machines, performing a detailed functionality check is a good way to rule out, or pin point, what issues may be occurring with the ...
    • FB: Troubleshooting Machine Not Cooling

      Troubleshooting :: Frozen Beverage :: Not Cooling Introduction If your Spaceman USA machine is not cooling, there are often some very simple reasons that can be quickly checked to resolve the issue.  Please follow and verify the steps below to ...