Fan Motor Specs

Fan Motor Specs

Documentation :General :: Fan Motor Specs


Spaceman machines have either one or three compressors (main or auxiliary) that use condenser fans to exhaust heat generated by the machine while it’s in use. Below you’ll find information such as the voltage, power, speed of the fan, current in amps, and air volume metrics of the fan as it relates to exhausting heat from the machine.

Model

Compressor Model #

Part #

Voltage

Power

Speed

RPM

Current

A

Air Volume

m3/h

CFM

6210-C

YWF4E-200S-92/15-G

3.2.03.04.007

115/60/1

45

1740

0.35

509

300

6228-C

YWF4E-300S

3.2.03.04.002

220/60/1

115

1500

0.56

1700

1000

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6236-C

YWF4E-350S

3.2.03.04.001

220/60/1

180

1550

0.85

2300

1354

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6235-C

YWF4E-350S

3.2.03.04.001

220/60/1

180

1550

0.85

2300

1354

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6250-C

YWF4E-350S

3.2.03.04.001

220/60/1

180

1550

0.85

2300

1354

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6378-C

YWF4E-350S

3.2.03.04.001

220/60/1

180

1550

0.85

2300

1354

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6650-C

YWF4E-250S

3.2.03.04.004

115/60/1

80

1730

0.70

912

537

6690-C

YWF4E-300S

3.2.03.04.002

220/60/1

115

1500

0.56

1700

1000

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6455-C

YWF4E-300S

3.2.03.04.003

115/60/1

95

1550

0.85

1700

1000

6695-C

YWF4E-350S

3.2.03.04.001

220/60/1

180

1550

0.85

2300

1354

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190

6795-C

YWF4E-350S

3.2.03.04.001

220/60/1

180

1550

0.85

2300

1354

 

BT220-15050S2HL

3.2.03.01.001

220/60/1

40

3000

0.30

323

190

 

UF-1751B22H

3.2.03.01.005

115/60/1

38

2700

0.48

323

190


    • Related Articles

    • SS: Troubleshooting 3 Phase Motor

      Troubleshooting :: Soft Serve :: Troubleshooting a 3 Phase Motor Introduction The below troubleshooting steps are to verify the functionality of the 3 Phase Motors installed on Spaceman Soft Serve machines.  These steps assume that you have already ...
    • Motor Amp Draws

      Documentation :: Motor Amp Draws Introduction When diagnosing potential machine issues, it can be helpful to disconnect the belts from the motor and confirm the motor amp draws. The below chart indicates the ideal amp-draw that should be measured on ...
    • FB: Replacing Motor

      How-To Guide :: Frozen Beverage :: Replacing Motor Spaceman Frozen Beverage machines utilize a single-phase motor with start and run capacitors to drive the main auger to agitate the product.  These motors drive a pulley which turns a belt attached ...
    • SS: Replacing Three Phase Motor

      How-To Guide :: Soft Serve :: Replacing 3-Phase Motor Spaceman Soft Serve machines utilize either a single-phase motor with start and run capacitors or a three-phase motor driven by an inverter to drive the main auger to agitate the product.  These ...
    • SS: Troubleshooting 1-Phase Motor

      Troubleshooting :: Soft Serve :: Troubleshooting a 1-Phase Motor Introduction The single phase motors used on Spaceman machines generally have a starting and running winding, a centrifugal switch, a start capacitor, and a run capacitor.  There is no ...